{"id":6329,"date":"2017-02-02T11:52:45","date_gmt":"2017-02-02T09:52:45","guid":{"rendered":"https:\/\/krausz.com\/de\/hymax-fallstudie-haines-city-florida\/"},"modified":"2017-02-02T11:52:45","modified_gmt":"2017-02-02T09:52:45","slug":"hymax-fallstudie-haines-city-florida","status":"publish","type":"post","link":"https:\/\/krausz.com\/de\/hymax-fallstudie-haines-city-florida\/","title":{"rendered":"HYMAX Fallstudie: Haines City, Florida"},"content":{"rendered":"<p><strong><a href=\"https:\/\/krausz.com\/wp-content\/uploads\/2015\/12\/Sept-2014-KC-case-study.jpg\" rel=\"attachment wp-att-2012\"><img loading=\"lazy\" decoding=\"async\" class=\"size-medium wp-image-2012 alignleft\" src=\"https:\/\/krausz.com\/wp-content\/uploads\/2015\/12\/Sept-2014-KC-case-study-300x198-1.jpg\" alt=\"Sept 2014 KC - case study\" width=\"300\" height=\"198\" \/><\/a>Der Kunde<\/strong><br \/>\nDie Wasserverwaltung der Stadt Haines City, Florida, bedient 20.000 Kunden und \u00fcberwacht und wartet:<\/p>\n<ul>\n<li>89 Meilen Wasserhauptleitungen im Gr\u00f6\u00dfenbereich von 2 bis 30 Zoll<\/li>\n<li>7 Meilen Leitungen f\u00fcr regeneriertes Wasser<\/li>\n<li>40 Meilen Druckleitungen und<\/li>\n<li>51 Meilen Gravitationsschmutzwasserleitungen mit 850 Sch\u00e4chten<\/li>\n<\/ul>\n<p>James Coker, der Vorabeiter es Versorgungsunternehmens von Haines City arbeitet seit 2001 f\u00fcr die Stadt Haines City. Er und sein Team stellen einen 24-Stunden-Support f\u00fcr Reparaturen zur Verf\u00fcgung und unterst\u00fctzen au\u00dferdem bei Bedarf die umliegenden Kommunen.<\/p>\n<p>&nbsp;<\/p>\n<p><strong>Die Situation<\/strong><br \/>\nIm Jahr 2012 bohrte eine Kabelfirma in den Boden eines Wohngebiets in Haines City und traf ein 10-Zoll-Gravitationsschmutzwasserrohr aus Ton, was daraufhin zerbrach. Als Coker und sein Team ankamen, begannen sie mit dem Ausgraben des Rohres in etwa 4 Metern Tiefe. Der Schaden war so schwer, dass das besch\u00e4digte Rohr herausgeschnitten, durch ein Polyvinylchlorid(PVC)-Rohr ersetzt und an das Tonrohr mit Kupplungen an jeder Seite angeschlossen werden musste.<\/p>\n<p><strong>Die Herausforderung<\/strong><br \/>\nCoker war mit zwei Herausforderungen zur Gew\u00e4hrleistung einer starken, sicheren und haltbaren Verbindung \u00fcber einen langen Zeitraum konfrontiert.<\/p>\n<p>1. Die Verbindung musste flexibel sein.<br \/>\nDer Boden um das Rohr herum war h\u00e4ufig nass und matschig, was bedeutete, dass sich der Boden oft bewegen w\u00fcrde. Die Verbindungen zwischen dem PVC und dem Tonrohr mussten flexibel genug sein, um diese Bodenbewegungen zu absorbieren, andernfalls w\u00fcrde die Verbindung geschw\u00e4cht oder auf lange Sicht brechen.<\/p>\n<p>2. Die Verbindung musste dem Abwasser einen freien Fluss erm\u00f6glichen.<br \/>\nKupplungsschlauchklemmen aus Gummi konnten verwendet werden, um die Flexibilit\u00e4t zu erm\u00f6glichen, die aufgrund der Bodenbewegungen erforderlich war und um die verschiedenen Au\u00dfendurchmesser (AD) der PVC- und Tonrohre aufzunehmen. Das Problem bei dieser Art von Verbindungen ist, dass der Boden ein Verbiegen der Kupplung verursachen kann, die den Abwasserfluss behindert und sich deshalb Ablagerungen festsetzen k\u00f6nnten.<\/p>\n<p>Coker suchte eine Kupplung mit ausreichend Flexibilit\u00e4t, um dem beweglichen Untergrund standzuhalten und die gleichzeitig fest genug war, um einen freien Durchfluss des Abwassers zu gew\u00e4hrleisten.<\/p>\n<p><strong>Die L\u00f6sung<\/strong><br \/>\nCoker verwendete zwei HYMAX Kupplungen, um das PVC-Rohr an beiden Enden mit dem Tonrohr zu verbinden.<\/p>\n<p>Der HYMAX konnte zwei grundlegende Vorteile f\u00fcr diese Reparatur bieten.<\/p>\n<p><em>1. Abwinkelungskapazit\u00e4t des HYMAX<\/em><br \/>\nHYMAX erlaubt jedem der verbundenen Rohrenden eine Dehnung um vier Grad und erm\u00f6glicht so eine kontinuierliche dynamische Abwinkelung. Gleichzeitig ist die Verbindung stark und haltbar und garantiert daher einen freien Durchfluss f\u00fcr das Abwasser, ist aber trotzdem flexibel genug, um Bodenbewegungen zu absorbieren.<\/p>\n<p><em>2. Breites Spektrum von AD beim HYMAX<\/em><br \/>\nHYMAX erreicht eine feste Abdichtung trotz verschiedener Materialien der verbundenen Rohre (PVC und Ton) und der AD-Differenz zwischen den beiden Rohrarten. Die beiden Dichtungen des HYMAX machten einen festen Sitz trotz dieser Unterschiede m\u00f6glich.<\/p>\n<p><a href=\"https:\/\/krausz.com\/wp-content\/uploads\/2015\/12\/Sept-2014-KC-case-study-3.jpg\" rel=\"attachment wp-att-2011\"><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-2011 alignleft\" src=\"https:\/\/krausz.com\/wp-content\/uploads\/2015\/12\/Sept-2014-KC-case-study-3-300x225-1.jpg\" alt=\"Sept 2014 KC - case study 3\" width=\"241\" height=\"181\" \/><\/a>Nachdem das besch\u00e4digte Tonrohr entfernt worden war, wurde ein St\u00fcck PVC-Rohr abgemessen und zurechtgeschnitten. Cokers Crew l\u00f6ste die 2-Schrauben-Halterungen und schob die zwei HYMAX Kupplungen auf jedes Rohrende (siehe Foto links). Als die Kupplungen angebracht waren, wurde das Rohr in den Boden gesenkt, wo dann die Reparatur stattfand.<\/p>\n<p>Dort angekommen, wurden die HYMAX an die richtige Stelle geschoben, um das PVC-Rohr mit dem Tonrohr im Boden zu verbinden (siehe Foto rechts). Der Abstand zwischen dem PVC- und dem Tonrohr wurde in der Kupplung ausgemessen, da die Abwinkelungsf\u00e4higkeit der Kupplung eingeschr\u00e4nkt gewesen w\u00e4re, h\u00e4tten sie sich innerhalb des HYMAX ber\u00fchrt. An diesem Punkt zog die Crew die beiden nach oben ausgerichteten Schrauben an jeder HYMAX Kupplung fest, um die Reparatur abzuschlie\u00dfen.<\/p>\n<p><strong>Schlussfolgerungen<\/strong><br \/>\nDer HYMAX bot eine drei Vorteile f\u00fcr die Reparatur des Abwasserrohrs.<a href=\"https:\/\/krausz.com\/wp-content\/uploads\/2015\/12\/Sept-2014-KC-case-study2.jpg\" rel=\"attachment wp-att-2013\"><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-2013 alignright\" src=\"https:\/\/krausz.com\/wp-content\/uploads\/2015\/12\/Sept-2014-KC-case-study2.jpg\" alt=\"Sept 2014 KC - case study2\" width=\"278\" height=\"167\" \/><\/a><\/p>\n<p><em>1. Abwinkelungskapazit\u00e4t und gleichzeitig ein freier Durchflussweg<\/em><br \/>\nDer HYMAX bot eine starke Verbindung, die sowohl die Flexibilit\u00e4t besa\u00df, Bodenbewegungen zu absorbieren, jedoch fest genug war, um einen freien Durchflussweg zu gew\u00e4hrleisten.<\/p>\n<p><em>2. Aufnahme eines breiten Spektrums an AD und Rohrmaterialien<\/em><br \/>\nDer HYMAX konnte ein breites Spektrum an ADs und Rohren aus verschiedensten Materialien aufnehmen und erm\u00f6glichte so die Verwendung unter den unterschiedlichsten Bedingungen.<\/p>\n<p><em>3. Einfache Installation<\/em><br \/>\nDer nach oben ausgerichtete Zwei-Schrauben-Verschlussmechanismus des HYMAX machte die Installation schnell und einfach.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Der Kunde Die Wasserverwaltung der Stadt Haines City, Florida, bedient 20.000 Kunden und \u00fcberwacht und wartet: 89 Meilen Wasserhauptleitungen im Gr\u00f6\u00dfenbereich von 2 bis 30 Zoll 7 Meilen Leitungen f\u00fcr regeneriertes Wasser 40 Meilen Druckleitungen und 51 Meilen Gravitationsschmutzwasserleitungen mit 850 Sch\u00e4chten<\/p>\n<div class=\"view-full-post\"><a href=\"https:\/\/krausz.com\/de\/hymax-fallstudie-haines-city-florida\/\" class=\"view-full-post-btn\">(\u05dc\u05d4\u05de\u05e9\u05da \u05e7\u05e8\u05d9\u05d0\u05d4&#8230;)<\/a><\/div>\n","protected":false},"author":3,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false,"footnotes":""},"categories":[38,43],"tags":[],"class_list":["post-6329","post","type-post","status-publish","format-standard","hentry","category-newsletter-de","category-sep-14-de"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>HYMAX Fallstudie: Haines City, Florida - Krausz Industries<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/krausz.com\/hymax-coupling-to-repair-sewer-pipe-in-haines-city-florida\/\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"HYMAX Fallstudie: Haines City, Florida - Krausz Industries\" \/>\n<meta property=\"og:description\" content=\"Der Kunde Die Wasserverwaltung der Stadt Haines City, Florida, bedient 20.000 Kunden und \u00fcberwacht und wartet: 89 Meilen Wasserhauptleitungen im Gr\u00f6\u00dfenbereich von 2 bis 30 Zoll 7 Meilen Leitungen f\u00fcr regeneriertes Wasser 40 Meilen Druckleitungen und 51 Meilen Gravitationsschmutzwasserleitungen mit 850 Sch\u00e4chten(\u05dc\u05d4\u05de\u05e9\u05da \u05e7\u05e8\u05d9\u05d0\u05d4...)\" \/>\n<meta property=\"og:url\" content=\"https:\/\/krausz.com\/hymax-coupling-to-repair-sewer-pipe-in-haines-city-florida\/\" \/>\n<meta property=\"og:site_name\" content=\"Krausz Industries\" \/>\n<meta property=\"article:published_time\" content=\"2017-02-02T09:52:45+00:00\" \/>\n<meta name=\"author\" content=\"josh\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\" \/>\n\t<meta name=\"twitter:data1\" content=\"josh\" \/>\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\" \/>\n\t<meta name=\"twitter:data2\" content=\"3\u00a0Minuten\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/krausz.com\\\/hymax-coupling-to-repair-sewer-pipe-in-haines-city-florida\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/krausz.com\\\/hymax-coupling-to-repair-sewer-pipe-in-haines-city-florida\\\/\"},\"author\":{\"name\":\"josh\",\"@id\":\"https:\\\/\\\/krausz.com\\\/#\\\/schema\\\/person\\\/6870c24116638440cf17c941b061d115\"},\"headline\":\"HYMAX Fallstudie: Haines City, Florida\",\"datePublished\":\"2017-02-02T09:52:45+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/krausz.com\\\/hymax-coupling-to-repair-sewer-pipe-in-haines-city-florida\\\/\"},\"wordCount\":669,\"image\":{\"@id\":\"https:\\\/\\\/krausz.com\\\/hymax-coupling-to-repair-sewer-pipe-in-haines-city-florida\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/krausz.com\\\/wp-content\\\/uploads\\\/2015\\\/12\\\/Sept-2014-KC-case-study-300x198-1.jpg\",\"articleSection\":[\"Newsletter\",\"Sep-14\"],\"inLanguage\":\"de\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/krausz.com\\\/hymax-coupling-to-repair-sewer-pipe-in-haines-city-florida\\\/\",\"url\":\"https:\\\/\\\/krausz.com\\\/hymax-coupling-to-repair-sewer-pipe-in-haines-city-florida\\\/\",\"name\":\"HYMAX Fallstudie: Haines City, Florida - Krausz Industries\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/krausz.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/krausz.com\\\/hymax-coupling-to-repair-sewer-pipe-in-haines-city-florida\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/krausz.com\\\/hymax-coupling-to-repair-sewer-pipe-in-haines-city-florida\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/krausz.com\\\/wp-content\\\/uploads\\\/2015\\\/12\\\/Sept-2014-KC-case-study-300x198-1.jpg\",\"datePublished\":\"2017-02-02T09:52:45+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/krausz.com\\\/#\\\/schema\\\/person\\\/6870c24116638440cf17c941b061d115\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/krausz.com\\\/hymax-coupling-to-repair-sewer-pipe-in-haines-city-florida\\\/#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/krausz.com\\\/hymax-coupling-to-repair-sewer-pipe-in-haines-city-florida\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/krausz.com\\\/hymax-coupling-to-repair-sewer-pipe-in-haines-city-florida\\\/#primaryimage\",\"url\":\"https:\\\/\\\/krausz.com\\\/wp-content\\\/uploads\\\/2015\\\/12\\\/Sept-2014-KC-case-study-300x198-1.jpg\",\"contentUrl\":\"https:\\\/\\\/krausz.com\\\/wp-content\\\/uploads\\\/2015\\\/12\\\/Sept-2014-KC-case-study-300x198-1.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/krausz.com\\\/hymax-coupling-to-repair-sewer-pipe-in-haines-city-florida\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/krausz.com\\\/de\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"HYMAX Fallstudie: Haines City, Florida\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/krausz.com\\\/#website\",\"url\":\"https:\\\/\\\/krausz.com\\\/\",\"name\":\"Krausz Industries\",\"description\":\"Repair the past. Connect the future\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/krausz.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"de\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/krausz.com\\\/#\\\/schema\\\/person\\\/6870c24116638440cf17c941b061d115\",\"name\":\"josh\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"de\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bcaa13e00da7ea5c31e25195190e0a56f84e2fa6aa4af7f854ead2085d842b43?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bcaa13e00da7ea5c31e25195190e0a56f84e2fa6aa4af7f854ead2085d842b43?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/bcaa13e00da7ea5c31e25195190e0a56f84e2fa6aa4af7f854ead2085d842b43?s=96&d=mm&r=g\",\"caption\":\"josh\"},\"url\":\"https:\\\/\\\/krausz.com\\\/de\\\/author\\\/josh\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"HYMAX Fallstudie: Haines City, Florida - Krausz Industries","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/krausz.com\/hymax-coupling-to-repair-sewer-pipe-in-haines-city-florida\/","og_locale":"de_DE","og_type":"article","og_title":"HYMAX Fallstudie: Haines City, Florida - Krausz Industries","og_description":"Der Kunde Die Wasserverwaltung der Stadt Haines City, Florida, bedient 20.000 Kunden und \u00fcberwacht und wartet: 89 Meilen Wasserhauptleitungen im Gr\u00f6\u00dfenbereich von 2 bis 30 Zoll 7 Meilen Leitungen f\u00fcr regeneriertes Wasser 40 Meilen Druckleitungen und 51 Meilen Gravitationsschmutzwasserleitungen mit 850 Sch\u00e4chten(\u05dc\u05d4\u05de\u05e9\u05da \u05e7\u05e8\u05d9\u05d0\u05d4...)","og_url":"https:\/\/krausz.com\/hymax-coupling-to-repair-sewer-pipe-in-haines-city-florida\/","og_site_name":"Krausz Industries","article_published_time":"2017-02-02T09:52:45+00:00","author":"josh","twitter_card":"summary_large_image","twitter_misc":{"Verfasst von":"josh","Gesch\u00e4tzte Lesezeit":"3\u00a0Minuten"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/krausz.com\/hymax-coupling-to-repair-sewer-pipe-in-haines-city-florida\/#article","isPartOf":{"@id":"https:\/\/krausz.com\/hymax-coupling-to-repair-sewer-pipe-in-haines-city-florida\/"},"author":{"name":"josh","@id":"https:\/\/krausz.com\/#\/schema\/person\/6870c24116638440cf17c941b061d115"},"headline":"HYMAX Fallstudie: Haines City, Florida","datePublished":"2017-02-02T09:52:45+00:00","mainEntityOfPage":{"@id":"https:\/\/krausz.com\/hymax-coupling-to-repair-sewer-pipe-in-haines-city-florida\/"},"wordCount":669,"image":{"@id":"https:\/\/krausz.com\/hymax-coupling-to-repair-sewer-pipe-in-haines-city-florida\/#primaryimage"},"thumbnailUrl":"https:\/\/krausz.com\/wp-content\/uploads\/2015\/12\/Sept-2014-KC-case-study-300x198-1.jpg","articleSection":["Newsletter","Sep-14"],"inLanguage":"de"},{"@type":"WebPage","@id":"https:\/\/krausz.com\/hymax-coupling-to-repair-sewer-pipe-in-haines-city-florida\/","url":"https:\/\/krausz.com\/hymax-coupling-to-repair-sewer-pipe-in-haines-city-florida\/","name":"HYMAX Fallstudie: Haines City, Florida - Krausz Industries","isPartOf":{"@id":"https:\/\/krausz.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/krausz.com\/hymax-coupling-to-repair-sewer-pipe-in-haines-city-florida\/#primaryimage"},"image":{"@id":"https:\/\/krausz.com\/hymax-coupling-to-repair-sewer-pipe-in-haines-city-florida\/#primaryimage"},"thumbnailUrl":"https:\/\/krausz.com\/wp-content\/uploads\/2015\/12\/Sept-2014-KC-case-study-300x198-1.jpg","datePublished":"2017-02-02T09:52:45+00:00","author":{"@id":"https:\/\/krausz.com\/#\/schema\/person\/6870c24116638440cf17c941b061d115"},"breadcrumb":{"@id":"https:\/\/krausz.com\/hymax-coupling-to-repair-sewer-pipe-in-haines-city-florida\/#breadcrumb"},"inLanguage":"de","potentialAction":[{"@type":"ReadAction","target":["https:\/\/krausz.com\/hymax-coupling-to-repair-sewer-pipe-in-haines-city-florida\/"]}]},{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/krausz.com\/hymax-coupling-to-repair-sewer-pipe-in-haines-city-florida\/#primaryimage","url":"https:\/\/krausz.com\/wp-content\/uploads\/2015\/12\/Sept-2014-KC-case-study-300x198-1.jpg","contentUrl":"https:\/\/krausz.com\/wp-content\/uploads\/2015\/12\/Sept-2014-KC-case-study-300x198-1.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/krausz.com\/hymax-coupling-to-repair-sewer-pipe-in-haines-city-florida\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/krausz.com\/de\/"},{"@type":"ListItem","position":2,"name":"HYMAX Fallstudie: Haines City, Florida"}]},{"@type":"WebSite","@id":"https:\/\/krausz.com\/#website","url":"https:\/\/krausz.com\/","name":"Krausz Industries","description":"Repair the past. Connect the future","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/krausz.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"de"},{"@type":"Person","@id":"https:\/\/krausz.com\/#\/schema\/person\/6870c24116638440cf17c941b061d115","name":"josh","image":{"@type":"ImageObject","inLanguage":"de","@id":"https:\/\/secure.gravatar.com\/avatar\/bcaa13e00da7ea5c31e25195190e0a56f84e2fa6aa4af7f854ead2085d842b43?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/bcaa13e00da7ea5c31e25195190e0a56f84e2fa6aa4af7f854ead2085d842b43?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/bcaa13e00da7ea5c31e25195190e0a56f84e2fa6aa4af7f854ead2085d842b43?s=96&d=mm&r=g","caption":"josh"},"url":"https:\/\/krausz.com\/de\/author\/josh\/"}]}},"_links":{"self":[{"href":"https:\/\/krausz.com\/de\/wp-json\/wp\/v2\/posts\/6329","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/krausz.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/krausz.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/krausz.com\/de\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/krausz.com\/de\/wp-json\/wp\/v2\/comments?post=6329"}],"version-history":[{"count":0,"href":"https:\/\/krausz.com\/de\/wp-json\/wp\/v2\/posts\/6329\/revisions"}],"wp:attachment":[{"href":"https:\/\/krausz.com\/de\/wp-json\/wp\/v2\/media?parent=6329"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/krausz.com\/de\/wp-json\/wp\/v2\/categories?post=6329"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/krausz.com\/de\/wp-json\/wp\/v2\/tags?post=6329"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}